Delta UNOnext Indoor Air Quality Monitor
CO2 sensors are used to control ventilation systems and monitor indoor air quality. They can be stand-alone sensors or integrated into thermostats or air quality monitoring platforms.
Learn MoreIf you are experiencing issues with the comparison tool, please disable your adblocker.
Delta UNOnext Indoor Air Quality Monitor
The UNOnext Indoor Air Quality Monitor is an indoor air quality monitor with a display that can be used for long-term monitoring.
Hub Highlights:
- CO2 value displayed on device and mobile app
- Easily connected to any building automation system for monitoring or ventilation control
- Good performance on Hub CO2 accuracy testing protocols
- Includes CO2, temperature, humidity, particulate matter, ozone, and other sensors
Last Edited on: Sep 30, 2021
Model Number | UNOnext Indoor Air Quality Monitor |
Last Updated | 8/3/2021 |
Sensor Type | Manufacturer: Sensirion |
Power Input | 12 VDC |
Outputs | Uno Cloud interface |
Altitude Correction Method | Unknown |
Measurement Range | 350-10000 ppm |
Reported Accuracy | ± 30 ppm ± 3% |
Display of C02 Value | On device and Apple/Android Application |
Uses Automatic Background Calibration (ABC) | Yes |
Last Edited on: Sep 30, 2021
Model | UNOnext Indoor Air Quality Monitor |
Date of Test (including warm-up period if device uses automatic background calibration) | July 28-August 10, 2021 |
Sample Size | 1 |
Error of CO2 measurement @1100 ppm (average) (ppm)
|
-2 |
Error of CO2 measurement @ 1100 ppm (standard deviation) (ppm)
|
N/A |
Accuracy Metric
|
- |
Noise of CO2 measurement @1100 ppm (Average) (ppm)
|
2.4 |
CO2 Full results
|
See Box Plot |
Operating Power for Sensor (watts) | 1.36 |
Operating Power for Gateway (watts) | N/A |
Operating Power for Sensor + Gateway (watts)
|
1.36 |
Operating Power Metric
|
<±3.0 W |
Maximum Number of Sensors per Gateway | N/A |
Last Edited on: Sep 30, 2021
Data Source: Staff at the UC Davis Western Cooling Efficiency Center
User Interface
Can the sensor display the CO2 level to occupants? If yes describe.
Yes - Display on the sensor
User Interface
Can the sensor display a visual indicator to occupants that the CO2 level has exceeded a programmed threshold? If yes, describe (what does the indicator look like, what the default thresholds are, and can the threshold be changed).
Yes - LED light turns yellow when CO2 exceeds configurable "yellow limit" (default: 800 ppm), red when exceeds configurable "red limit" (default: 1000 ppm), and purple when exceeds configurable "purple limit" (default: 4000 ppm). LED light also changes color when particulate matter exceeds configurable thresholds. Otherwise LED light is green.
Reporting Capabilities
Can the sensor alert facilities (such as an email, text, or call phone application) when the CO2 level has exceeded a programmed threshold? If yes, describe (what does the indicator look like and can the threshold be changed).
Yes - The website has a feature to enable e-mail alerts for elevated CO2 levels. Alerts need to be configured for each individual sensor.
Reporting Capabilities, Integration Capabilities
How can the CO2 sensor data be logged? If proprietary software, describe (what type of account is needed, what logging intervals are available, what does it look like, and describe its capabilities including data download capabilities).
Wifi with proprietary software. Data collection interval is fixed at 6 minutes Data can be downloaded to a CSV file.
Integration Capabilities
Can the CO2 sensor interface with a building automation system (BAS) or demand control ventilation (DCV) system controller? If yes, describe if integration capabilities are vendor specific.
Yes
Integration Capabilities
If sensor can interface with a BAS or DCV system controller, is additional hardware required?
No
Installation
Does the sensor require specialized software for installation? If yes, describe
No
Installation
Does the sensor require specialized training for installation? If yes, describe
No
Operation
Does the sensor require on-going maintenance? If yes, describe
No
Operation
Does the sensor require service contracts for ongoing data access? If yes, describe
No