| Citation | Abstract |
| Pistochini, T., Ellis, M., Meyers, F., Frasier, A., Cappa, C., & Bennett, D. (2023). Method of test for CO2-based demand control ventilation systems: Benchmarking the state-of-the-art and the undervalued potential of proportional-integral control. Energy and Buildings, 301, 113717. | Carbon dioxide (CO2) based demand control ventilation (DCV) adjusts a building’s outdoor air ventilation rate in response to indoor CO2 concentration to save energy while maintaining indoor air quality. Packaged heating, ventilation, and air-conditioning systems often contain DCV controllers with embedded proprietary algorithms that lack transparent performance data. A test method was developed to assess the ability of a DCV controller to maintain the indoor CO2 concentration at a setpoint in response to a series of CO2 generation functions that represent three different building occupancy densities and two occupancy schedules. Six commercially available controllers were tested to demonstrate the method and provide directly comparable results. The performance (in terms of CO2 control and damper movement) of each controller tested was compared to the performance of an ideal controller which knows the CO2 generation function. Finally, the performance of a proportional-integral (PI) controller with preset gains was developed and tested to determine the potential maximum performance achievable with this control strategy. The best performing commercially available controller achieved CO2 control (within 75 ppm of the setpoint) approximately 80 % of the time with damper movement slightly less than an ideal controller. However, most of the commercially available controllers had marginal or poor performance for CO2 control and damper movement. Two controllers had damper movement more than three times the ideal controller. Notably, a PI algorithm configured and tested by the research team achieved superior performance with CO2 control 92 % of the time and damper movement 1.5 times the ideal controller. |
| Wen, Y., Lafrenz, R., & Patibanda, S. (2022). Enhancing the role of plug loads in grid-interactive buildings using smart plugs. Proceedings of the 2022 ACEEE Summer Study on Energy Efficiency in Buildings. Asilomar, CA. | Smart plugs are popular Internet of Things devices most prevalent in residentialbuildings, and more smart plug solutions are emerging for commercial applications. In bothresidential and commercial buildings, the number of plug loads is growing at an unprecedentedrate surpassing other end uses due to the reliance on electronic devices for day-to-day life,productivity, and entertainment. Not all electronic devices have a built-in low power mode whennot providing full services. Beyond remote toggling and scheduling of equipment power supply,smart plugs provide an easy way to enable the ever-increasing number of plug loads to play arole in grid-interactive buildings, especially in existing buildings. To realize this, two features arecritical: the native energy metering capability and the dispatching mechanism. The energymetering capability determines if and how much a particular load can provide relief to the grid.The dispatching mechanism allows the grid or the building management system to activate thesmart plugs to achieve the required load reduction.This paper presents evaluations of six smart plug products and discusses the current andnear-future potential for smart plugs to enable grid-interactive services. The smart plugs’ nativeenergy metering performance was tested and quantified under various load levels, electricalconditions, and power and connectivity interruptions. Their ability to be dispatched was alsocharacterized, either directly or through the innate integration mechanisms. Lastly, we measuredthese smart plugs’ internal power consumptions under different normal operating conditions toprovide insights into the necessary energy penalty to enable the grid services. |
| Peffer, T., Pantelic, J., He, Y., & Bauman, F. (2022). When smart thermostats are dumb: Lessons learned from evaluating advanced thermostats. Proceedings of the 2022 ACEEE Summer Study on Energy Efficiency in Buildings. Asilomar, CA. | A decade after a certain round thermostat upended the industry, we now find dozens ofso-called smart or advanced thermostats, with remote control, occupancy sensing, and multipleoptimization strategies. Many studies evaluate these features in the residential sector. But howdoes one choose the right advanced thermostat for the application for a small commercialsetting?This paper describes the evaluation and testing of several advanced thermostats. Theresearch team reviewed the literature, interviewed 20 facilities managers, conducted sensoryaccuracy tests, and performed a heuristic evaluation of several advanced thermostats currently onthe market.What did we learn by studying these thermostats? We learned which features areimportant to facilities managers and what support they need to improve their performance. Wediscovered that thermostats differed in sensor accuracy: lighted colored screens may cause self-heating, which can throw off accuracy by as much as 4F; (even a degree or two Fahrenheit canmake a difference in saving energy). We studied thermal asymmetry: the sensitivity of thethermostat temperature sensor to a source of radiant heat, such as a large window, sunlight on awall or any warm surface in the room, such as large equipment. Finally, the heuristic evaluationrevealed some of these advanced thermostats fail basic usability tests. |
| Jha, G., Nicolas, F., Schmidt, R., Suvočarev, K., Diaz, D., Kisekka, I., Scow, K., & Nocco, M. A. (2022). Irrigation Decision Support Systems (IDSS) for California’s Water–Nutrient–Energy Nexus. Agronomy, 12(8), 1962. | California has unsustainable use of agricultural water and energy, as well as problems of severe drought, nitrate pollution and groundwater salinity. As the leading producer and exporter of agricultural produce in the United States, 5.6 percent of California’s energy is currently used for pumping groundwater. These problems and new regulatory policies (e.g., Sustainable Groundwater Management Act, Irrigated Lands Regulatory Program) pressure growers to schedule, account and maintain records of water, energy and nutrients needed for crop and soil management. Growers require varying levels of decision support to integrate different irrigation strategies into farm operations. Decision support can come from the public or private sector, where there are many tradeoffs between cost, underlying science, user friendliness and overall challenges in farm integration. Thus, effective irrigation management requires clear definitions, decision support and guidelines for how to incorporate and evaluate the water–nutrient–energy nexus benefits of different practices and combinations of practices under shifting water governance. The California Energy Commission-sponsored Energy Product Evaluation Hub (Cal-EPE Hub) project has a mission of providing science-based evaluation of energy-saving technologies as a direct result of improved water management for irrigation in agriculture, including current and future irrigation decision support systems in California. This project incorporates end-user perceptions into evaluations of existing decision support tools in partnership with government, agricultural and private stakeholders. In this article, we review the policy context and science underlying the available irrigation decision support systems (IDSS), discuss the benefits/tradeoffs and report on their efficacy and ease of use for the most prevalent cropping systems in California. Finally, we identify research and knowledge-to-action gaps for incorporating irrigation decision support systems into new incentives and requirements for reporting water and energy consumption as well as salinity and nitrogen management in the state of California. |
| Shimim, F. N., Fortin, M. P., Nocco, M., Whitaker, B., Gal, A., Diaz, D., Schmidt, R., & Jha, G. (2025). Data fusion approach for predicting high resolution estimates of crop evapotranspiration. Precision Agriculture, 26, Article 82. | Spatial estimates of crop water use during the growing season are crucial for precision irrigation management, especially under conditions of water scarcity and climate change. The on-farm trial detailed in this paper focuses on a processing tomato field in the Sacramento Valley of California. |
| Meyers, F., Pistochini, T., Breault, R., & Hollist, J. (2024). Laboratory evaluation and potential energy savings of high-efficiency motor and drive systems for packaged HVAC units. ASHRAE Transactions, 130, 279–286. | High-efficiency variable speed motors have been shown to save energy in supply air systems by operating motors at reduced speed when conditions allow. This study laboratory tested high-efficiency motor and drive systems applicable to supply air systems. A dynamometer was constructed and instrumented to conduct tests on 7.5 HP motors and variable frequency drives (VFDs). Five commercially available motors that used various drive technologies were chosen for the study. The technologies evaluated include traditional induction, synchronous permanent magnet, hybrid synchronous reluctance/permanent magnet, and switched reluctance. The motor, VFD, and combined system efficiency was measured from 9-100% of maximum torque and 30-100% of maximum speed. From the system efficiency results, curves of motor speed vs power were derived for a fixed-resistance duct system. The switched reluctance, permanent magnet and hybrid synchronous reluctance/permanent magnet motors and their drive pairs outperformed the induction motor and drive pairs in terms of efficiency. The switched reluctance motor was the most efficient motor at full-load while the hybrid synchronous reluctance/permanent magnet motor was the most efficient motor at the lowest load. Testing drive and motor pairs at multiple loads is important for characterizing the impact of product selection as the biggest relative differences are seen at the lowest loads. While there is great focus by the federal government on full-load motor efficiency, it is important to consider efficiency at part-load as applications of multi-speed systems increase. |